{"id":20248,"date":"2026-07-07T14:33:09","date_gmt":"2026-07-07T11:33:09","guid":{"rendered":"https:\/\/mbaplant.com\/?page_id=20248"},"modified":"2026-07-25T12:27:38","modified_gmt":"2026-07-25T09:27:38","slug":"bitumen-storage-pit","status":"publish","type":"page","link":"https:\/\/mbaplant.com\/en\/bitumen-storage-pit\/","title":{"rendered":"Bitumen Storage Pit"},"content":{"rendered":"\n<header class=\"wp-block-uagb-container uagb-block-a3nrdo09 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-info-box uagb-block-hhpbujfv uagb-infobox__content-wrap  uagb-infobox-icon-above-title uagb-infobox-image-valign-top\"><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><h1 class=\"uagb-ifb-title\">Bitumen Storage Pit<\/h1><\/div><\/div><\/div>\n<\/div><\/header>\n\n\n\n<section class=\"wp-block-uagb-container uagb-block-5f6fcdfd alignfull uagb-is-root-container\">\n<div class=\"wp-block-uagb-container uagb-layout-grid uagb-block-85975273\">\n<div class=\"wp-block-uagb-info-box uagb-block-f2ec258d uagb-infobox__content-wrap  uagb-infobox-icon-above-title uagb-infobox-image-valign-top\"><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><\/div><p class=\"uagb-ifb-desc\"><strong>Bitumen Storage Pit<\/strong> is a <strong>reinforced concrete storage structure<\/strong> designed for the safe storage of hot bitumen, maintaining its temperature, and supplying it back to the production process whenever required. It is widely used in <strong>bitumen storage terminals<\/strong>, <strong>asphalt plants<\/strong>, <strong>polymer modified bitumen (PMB) plants<\/strong>, <strong>bitumen emulsion plants<\/strong>, and <strong>bitumen logistics facilities<\/strong> as a cost-effective and long-lasting storage solution.<br><br>MBA designs and builds <strong>thermal oil heated bitumen storage pits<\/strong> according to project requirements. The system is constructed by excavating the ground and casting reinforced concrete. <strong>Thermal oil heating coils<\/strong> installed inside the pit keep the bitumen at the required operating temperature, ensuring continuous flow and reliable pumping to the production line.<\/p><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-8c135f87 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" src=\"https:\/\/mbaplant.com\/wp-content\/uploads\/2026\/07\/Bitumen-storage-pit-2-1024x683.webp\" alt=\"Thermal oil heating coils installed inside a reinforced concrete bitumen storage pit to maintain the required bitumen temperature for continuous operation.\" class=\"uag-image-20258\" width=\"550\" height=\"400\" title=\"Bitumen storage pit (2)\" loading=\"lazy\" role=\"img\" \/><\/figure><\/div>\n<\/div>\n<\/section>\n\n\n\n<section class=\"wp-block-uagb-container uagb-block-b1dbcb8c alignfull uagb-is-root-container\">\n<div class=\"wp-block-uagb-container uagb-layout-grid uagb-block-8ddcd077\">\n<div class=\"wp-block-uagb-info-box uagb-block-879ce2ec uagb-infobox__content-wrap  uagb-infobox-icon-above-title uagb-infobox-image-valign-top\"><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><h2 class=\"uagb-ifb-title\">What is a Bitumen Storage Pit?<\/h2><\/div><div class=\"uagb-ifb-separator\"><\/div><p class=\"uagb-ifb-desc\">A <strong>Bitumen Storage Pit<\/strong> is an underground reinforced concrete storage system designed to store large quantities of bitumen while maintaining its temperature through an integrated <strong>thermal oil heating coil system<\/strong>.<br><br>Unlike conventional steel storage tanks, concrete bitumen pits offer an economical solution for high-capacity storage applications. The circulating thermal oil transfers heat evenly throughout the pit, preventing the bitumen from solidifying and ensuring uninterrupted production.<\/p><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-image uagb-block-223b5d5f wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" src=\"https:\/\/mbaplant.com\/wp-content\/uploads\/2026\/07\/Bitumen-storage-pit-1024x576.webp\" alt=\"Reinforced concrete Bitumen Storage Pit under construction with integrated thermal oil heating coil infrastructure for large-capacity bitumen storage.\" class=\"uag-image-20253\" width=\"1024\" height=\"576\" title=\"Bitumen storage pit\" loading=\"lazy\" role=\"img\" \/><\/figure><\/div>\n<\/div>\n<\/section>\n\n\n\n<section class=\"wp-block-uagb-container uagb-block-68ffa552 alignfull uagb-is-root-container\">\n<div class=\"wp-block-uagb-container uagb-layout-grid uagb-block-45e21622\">\n<div class=\"wp-block-uagb-info-box uagb-block-9fce6f6e uagb-infobox__content-wrap  uagb-infobox-icon-above-title uagb-infobox-image-valign-top\"><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><h2 class=\"uagb-ifb-title\">Bitumen Storage Pit Technical Features<\/h2><\/div><div class=\"uagb-ifb-separator\"><\/div><p class=\"uagb-ifb-desc\">The most critical factor in large-capacity bitumen storage is maintaining the required temperature while minimizing energy consumption. MBA <strong>Bitumen Storage Pits<\/strong> are engineered to deliver reliable performance, efficient heat transfer, and long service life.<br><br><strong>High-Efficiency Thermal Oil Heating Coil System<\/strong><br>The <strong>thermal oil heating coils<\/strong> installed at the bottom of the bitumen storage pit are designed using precise engineering calculations. The seamless steel coil system distributes heat evenly throughout the storage pit, preventing localized cooling and maintaining a uniform bitumen temperature.<br><br><strong>Maximum Thermal Insulation<\/strong><br>Our <strong>heated bitumen storage pits<\/strong> are designed with high-performance insulation systems that minimize heat loss caused by ambient conditions and ground temperature. This reduces fuel consumption while keeping the stored bitumen at the required operating temperature.<br><br><strong>Heavy-Duty Reinforced Concrete Construction<\/strong><br>MBA <strong>underground bitumen storage pits<\/strong> are built using reinforced concrete structures engineered to withstand high storage capacities, thermal stresses, and long-term operation. The robust construction provides exceptional durability and low maintenance requirements.<br><br><strong>Optional Temperature and Level Monitoring<\/strong><br>For improved process control, the storage pit can be equipped with temperature sensors and radar level transmitters. These instruments continuously monitor bitumen temperature and storage level, allowing seamless integration with the asphalt plant or terminal automation system.<\/p><\/div><\/div>\n<\/div>\n<\/section>\n\n\n\n<section class=\"wp-block-uagb-container uagb-block-63cb6e86 alignfull uagb-is-root-container\">\n<div class=\"wp-block-uagb-container uagb-layout-grid uagb-block-1bad0809\">\n<div class=\"wp-block-uagb-info-box uagb-block-0d6187cf uagb-infobox__content-wrap  uagb-infobox-icon-above-title uagb-infobox-image-valign-top\"><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><h2 class=\"uagb-ifb-title\">How Does a Bitumen Storage Pit Heating System Work ?<\/h2><\/div><div class=\"uagb-ifb-separator\"><\/div><p class=\"uagb-ifb-desc\">For large-capacity bitumen storage projects where conventional vertical or horizontal storage tanks are insufficient, the <strong>Bitumen Storage Pit Heating System<\/strong> provides an efficient and reliable solution by maintaining the bitumen at the required operating temperature.<br><br><strong>1. Thermal Energy Generation<\/strong><br>Hot thermal oil produced by the <strong>thermal oil heater<\/strong> is circulated through the heating coil network installed inside the reinforced concrete bitumen storage pit. This closed-loop system provides continuous and energy-efficient heat transfer.<br><br><strong>2. Localized and Uniform Heating<\/strong><br>The <strong>thermal oil heating coils<\/strong> are strategically positioned, with higher coil density around the bitumen suction area to maintain optimum pumping temperature. This design heats only the required zone instead of the entire storage pit, reducing fuel consumption while keeping the bitumen between <strong>140\u00b0C and 160\u00b0C<\/strong>.<br><br><strong>3. Safe and Continuous Bitumen Transfer<\/strong><br>Once the bitumen reaches the required viscosity, it is transferred by <strong>high-performance bitumen transfer pumps<\/strong> to asphalt mixing plants, PMB plants, bitumen emulsion plants, storage tanks, or loading facilities, ensuring uninterrupted production and efficient operation.<\/p><\/div><\/div>\n<\/div>\n<\/section>\n\n\n\n<section class=\"wp-block-uagb-container uagb-block-98fb69f2 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-5088dc2e alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-info-box uagb-block-8d589315 uagb-infobox__content-wrap  uagb-infobox-icon-above-title uagb-infobox-image-valign-top\"><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><p class=\"uagb-ifb-title-prefix\"><strong><strong><strong><strong><strong>REINFORCED CONCRETE BITUMEN STORAGE PIT MANUFACTURER<\/strong><\/strong><\/strong><\/strong><\/strong><\/p><h2 class=\"uagb-ifb-title\">Get a Quote for Custom Reinforced Concrete Bitumen Storage Pits Designed for Your Project Requirements !<\/h2><\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-7696a393\">\n<div class=\"wp-block-uagb-container uagb-block-d28d9ab8\">\n<div class=\"wp-block-uagb-info-box uagb-block-7c1ec862 uagb-infobox__content-wrap  uagb-infobox-icon-left uagb-infobox-left uagb-infobox-stacked-tablet uagb-infobox-image-valign-top\"><div class=\"uagb-ifb-icon-wrap\"><div class=\"uagb-iconbox-icon-wrap uagb-infobox-shape-circle\"><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 448 512\"><path d=\"M380.9 97.1C339 55.1 283.2 32 223.9 32c-122.4 0-222 99.6-222 222 0 39.1 10.2 77.3 29.6 111L0 480l117.7-30.9c32.4 17.7 68.9 27 106.1 27h.1c122.3 0 224.1-99.6 224.1-222 0-59.3-25.2-115-67.1-157zm-157 341.6c-33.2 0-65.7-8.9-94-25.7l-6.7-4-69.8 18.3L72 359.2l-4.4-7c-18.5-29.4-28.2-63.3-28.2-98.2 0-101.7 82.8-184.5 184.6-184.5 49.3 0 95.6 19.2 130.4 54.1 34.8 34.9 56.2 81.2 56.1 130.5 0 101.8-84.9 184.6-186.6 184.6zm101.2-138.2c-5.5-2.8-32.8-16.2-37.9-18-5.1-1.9-8.8-2.8-12.5 2.8-3.7 5.6-14.3 18-17.6 21.8-3.2 3.7-6.5 4.2-12 1.4-32.6-16.3-54-29.1-75.5-66-5.7-9.8 5.7-9.1 16.3-30.3 1.8-3.7 .9-6.9-.5-9.7-1.4-2.8-12.5-30.1-17.1-41.2-4.5-10.8-9.1-9.3-12.5-9.5-3.2-.2-6.9-.2-10.6-.2-3.7 0-9.7 1.4-14.8 6.9-5.1 5.6-19.4 19-19.4 46.3 0 27.3 19.9 53.7 22.6 57.4 2.8 3.7 39.1 59.7 94.8 83.8 35.2 15.2 49 16.5 66.6 13.9 10.7-1.6 32.8-13.4 37.4-26.4 4.6-13 4.6-24.1 3.2-26.4-1.3-2.5-5-3.9-10.5-6.6z\"><\/path><\/svg><\/div><\/div><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><p class=\"uagb-ifb-title\">telePHONE-whatsapp<\/p><\/div><p class=\"uagb-ifb-desc\"><a href=\"tel:+905467260606\">+90 546 726 06 06<\/a><\/p><\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-be562e44\">\n<div class=\"wp-block-uagb-info-box uagb-block-0ca9e03f uagb-infobox__content-wrap  uagb-infobox-icon-left uagb-infobox-left uagb-infobox-stacked-tablet uagb-infobox-image-valign-top\"><div class=\"uagb-ifb-icon-wrap\"><div class=\"uagb-iconbox-icon-wrap uagb-infobox-shape-circle\"><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 512 512\"><path d=\"M511.2 387l-23.25 100.8c-3.266 14.25-15.79 24.22-30.46 24.22C205.2 512 0 306.8 0 54.5c0-14.66 9.969-27.2 24.22-30.45l100.8-23.25C139.7-2.602 154.7 5.018 160.8 18.92l46.52 108.5c5.438 12.78 1.77 27.67-8.98 36.45L144.5 207.1c33.98 69.22 90.26 125.5 159.5 159.5l44.08-53.8c8.688-10.78 23.69-14.51 36.47-8.975l108.5 46.51C506.1 357.2 514.6 372.4 511.2 387z\"><\/path><\/svg><\/div><\/div><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><p class=\"uagb-ifb-title\">telePHONE 2<\/p><\/div><p class=\"uagb-ifb-desc\"><a href=\"tel:+905412535806\">+90 541 253 58 06<\/a><\/p><\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-a9010649\">\n<div class=\"wp-block-uagb-info-box uagb-block-33af9cbc uagb-infobox__content-wrap  uagb-infobox-icon-left uagb-infobox-left uagb-infobox-stacked-tablet uagb-infobox-image-valign-top\"><div class=\"uagb-ifb-icon-wrap\"><div class=\"uagb-iconbox-icon-wrap uagb-infobox-shape-circle\"><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 512 512\"><path d=\"M464 64C490.5 64 512 85.49 512 112C512 127.1 504.9 141.3 492.8 150.4L275.2 313.6C263.8 322.1 248.2 322.1 236.8 313.6L19.2 150.4C7.113 141.3 0 127.1 0 112C0 85.49 21.49 64 48 64H464zM217.6 339.2C240.4 356.3 271.6 356.3 294.4 339.2L512 176V384C512 419.3 483.3 448 448 448H64C28.65 448 0 419.3 0 384V176L217.6 339.2z\"><\/path><\/svg><\/div><\/div><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><p class=\"uagb-ifb-title\">EmaiL<\/p><\/div><p class=\"uagb-ifb-desc\"><a href=\"mailto:export@mbaplant.com\">export@mbaplant.com<\/a><\/p><\/div><\/div>\n<\/div>\n<\/div>\n<\/div><\/div>\n<\/div><\/section>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-fmeklbkq alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-advanced-heading uagb-block-vohu5ddk\"><h2 class=\"uagb-heading-text\"><strong><strong>Frequently Asked Questions About Bitumen Storage Pits<\/strong><\/strong><\/h2><p class=\"uagb-desc-text\">Find answers to the most frequently asked questions about reinforced concrete bitumen storage pits, thermal oil heating systems, storage capacities, applications, and engineering solutions.<\/p><\/div>\n\n\n<div class=\"wp-block-uagb-faq uagb-faq__outer-wrap uagb-block-eoju6szn uagb-faq-icon-row-reverse uagb-faq-layout-accordion uagb-faq-expand-first-true uagb-faq-inactive-other-true uagb-faq__wrap uagb-buttons-layout-wrap uagb-faq-equal-height     \" data-faqtoggle=\"true\" role=\"tablist\"><div class=\"wp-block-uagb-faq-child uagb-faq-child__outer-wrap uagb-faq-item uagb-block-gsf0nekn \" role=\"tab\" tabindex=\"0\"><div class=\"uagb-faq-questions-button uagb-faq-questions\">\t\t\t<span class=\"uagb-icon uagb-faq-icon-wrap\">\n\t\t\t\t\t\t\t\t<svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewBox= \"0 0 448 512\"><path d=\"M432 256c0 17.69-14.33 32.01-32 32.01H256v144c0 17.69-14.33 31.99-32 31.99s-32-14.3-32-31.99v-144H48c-17.67 0-32-14.32-32-32.01s14.33-31.99 32-31.99H192v-144c0-17.69 14.33-32.01 32-32.01s32 14.32 32 32.01v144h144C417.7 224 432 238.3 432 256z\"><\/path><\/svg>\n\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t<span class=\"uagb-icon-active uagb-faq-icon-wrap\">\n\t\t\t\t\t\t\t\t<svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewBox= \"0 0 448 512\"><path d=\"M400 288h-352c-17.69 0-32-14.32-32-32.01s14.31-31.99 32-31.99h352c17.69 0 32 14.3 32 31.99S417.7 288 400 288z\"><\/path><\/svg>\n\t\t\t\t\t\t\t<\/span>\n\t\t\t<p class=\"uagb-question\"><strong>Why should a Bitumen Storage Pit be preferred over vertical storage tanks?<\/strong><\/p><\/div><div class=\"uagb-faq-content\"><p>For large-scale bitumen storage projects or regions where bitumen supply is seasonal, storing thousands of tons of bitumen in conventional vertical tanks can require significant investment and large installation areas.<br><br>A <strong>reinforced concrete Bitumen Storage Pit<\/strong> provides a more economical solution for high-capacity storage while reducing construction costs. Thanks to its <strong>thermal oil heating coil system<\/strong>, heat is concentrated around the suction zone, minimizing energy consumption and ensuring that the bitumen remains at the required pumping temperature.<\/p><\/div><\/div><div class=\"wp-block-uagb-faq-child uagb-faq-child__outer-wrap uagb-faq-item uagb-block-ovofo85y \" role=\"tab\" tabindex=\"0\"><div class=\"uagb-faq-questions-button uagb-faq-questions\">\t\t\t<span class=\"uagb-icon uagb-faq-icon-wrap\">\n\t\t\t\t\t\t\t\t<svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewBox= \"0 0 448 512\"><path d=\"M432 256c0 17.69-14.33 32.01-32 32.01H256v144c0 17.69-14.33 31.99-32 31.99s-32-14.3-32-31.99v-144H48c-17.67 0-32-14.32-32-32.01s14.33-31.99 32-31.99H192v-144c0-17.69 14.33-32.01 32-32.01s32 14.32 32 32.01v144h144C417.7 224 432 238.3 432 256z\"><\/path><\/svg>\n\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t<span class=\"uagb-icon-active uagb-faq-icon-wrap\">\n\t\t\t\t\t\t\t\t<svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewBox= \"0 0 448 512\"><path d=\"M400 288h-352c-17.69 0-32-14.32-32-32.01s14.31-31.99 32-31.99h352c17.69 0 32 14.3 32 31.99S417.7 288 400 288z\"><\/path><\/svg>\n\t\t\t\t\t\t\t<\/span>\n\t\t\t<p class=\"uagb-question\"><strong>Why is the design of thermal oil heating coils important?<\/strong><\/p><\/div><div class=\"uagb-faq-content\"><p>The <strong>diameter, length, and layout of the thermal oil heating coils<\/strong> directly affect the heat transfer efficiency of a <strong>Bitumen Storage Pit<\/strong>. An improperly designed heating coil system may result in uneven heating, increased fuel consumption, and unnecessary energy losses.<br><br>At MBA, we perform detailed thermal engineering calculations based on the storage capacity, site conditions, and local climate to design the most efficient <strong>thermal oil heating coil system<\/strong>. This ensures uniform temperature distribution, optimum bitumen viscosity, lower operating costs, and reliable long-term performance.<\/p><\/div><\/div><div class=\"wp-block-uagb-faq-child uagb-faq-child__outer-wrap uagb-faq-item uagb-block-idvaykz6 \" role=\"tab\" tabindex=\"0\"><div class=\"uagb-faq-questions-button uagb-faq-questions\">\t\t\t<span class=\"uagb-icon uagb-faq-icon-wrap\">\n\t\t\t\t\t\t\t\t<svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewBox= \"0 0 448 512\"><path d=\"M432 256c0 17.69-14.33 32.01-32 32.01H256v144c0 17.69-14.33 31.99-32 31.99s-32-14.3-32-31.99v-144H48c-17.67 0-32-14.32-32-32.01s14.33-31.99 32-31.99H192v-144c0-17.69 14.33-32.01 32-32.01s32 14.32 32 32.01v144h144C417.7 224 432 238.3 432 256z\"><\/path><\/svg>\n\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t<span class=\"uagb-icon-active uagb-faq-icon-wrap\">\n\t\t\t\t\t\t\t\t<svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewBox= \"0 0 448 512\"><path d=\"M400 288h-352c-17.69 0-32-14.32-32-32.01s14.31-31.99 32-31.99h352c17.69 0 32 14.3 32 31.99S417.7 288 400 288z\"><\/path><\/svg>\n\t\t\t\t\t\t\t<\/span>\n\t\t\t<p class=\"uagb-question\"><strong><strong>Can you upgrade the heating system of our existing reinforced concrete Bitumen Storage Pit?<\/strong><\/strong><\/p><\/div><div class=\"uagb-faq-content\"><p><strong>Yes.<\/strong> In addition to designing and constructing new <strong>Bitumen Storage Pits<\/strong>, MBA also provides <strong>retrofit and modernization services<\/strong> for existing reinforced concrete storage pits.<br><br>We replace outdated, inefficient, or damaged <strong>thermal oil heating coil systems<\/strong> with newly engineered high-efficiency coil layouts designed to improve heat transfer, reduce fuel consumption, and ensure uniform bitumen heating. Every retrofit project is custom-engineered according to the existing pit dimensions, storage capacity, and operating conditions.<\/p><\/div><\/div><div class=\"wp-block-uagb-faq-child uagb-faq-child__outer-wrap uagb-faq-item uagb-block-699a0142 \" role=\"tab\" tabindex=\"0\"><div class=\"uagb-faq-questions-button uagb-faq-questions\">\t\t\t<span class=\"uagb-icon uagb-faq-icon-wrap\">\n\t\t\t\t\t\t\t\t<svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewBox= \"0 0 448 512\"><path d=\"M432 256c0 17.69-14.33 32.01-32 32.01H256v144c0 17.69-14.33 31.99-32 31.99s-32-14.3-32-31.99v-144H48c-17.67 0-32-14.32-32-32.01s14.33-31.99 32-31.99H192v-144c0-17.69 14.33-32.01 32-32.01s32 14.32 32 32.01v144h144C417.7 224 432 238.3 432 256z\"><\/path><\/svg>\n\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t<span class=\"uagb-icon-active uagb-faq-icon-wrap\">\n\t\t\t\t\t\t\t\t<svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewBox= \"0 0 448 512\"><path d=\"M400 288h-352c-17.69 0-32-14.32-32-32.01s14.31-31.99 32-31.99h352c17.69 0 32 14.3 32 31.99S417.7 288 400 288z\"><\/path><\/svg>\n\t\t\t\t\t\t\t<\/span>\n\t\t\t<p class=\"uagb-question\"><strong>What storage capacities are available for Bitumen Storage Pits?<\/strong><\/p><\/div><div class=\"uagb-faq-content\"><p>MBA designs and constructs <strong>reinforced concrete Bitumen Storage Pits<\/strong> in standard capacities of <strong>500 tons, 1,000 tons, 1,500 tons, 2,000 tons, 2,500 tons, 3,000 tons, and 5,000 tons<\/strong>.<br><br>Custom storage capacities and dimensions can also be engineered to meet specific project requirements, site conditions, and operational needs.<\/p><\/div><\/div><\/div><\/div><\/div>\n\n\n\n<section class=\"wp-block-uagb-container uagb-block-820003bf alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-info-box uagb-block-39eb5617 uagb-infobox__content-wrap  uagb-infobox-icon-above-title uagb-infobox-image-valign-top\"><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><h2 class=\"uagb-ifb-title\">Other Bitumen Technologies<\/h2><\/div><div class=\"uagb-ifb-separator\"><\/div><p class=\"uagb-ifb-desc\">MBA offers a complete range of <strong>bitumen equipment and processing systems<\/strong> for asphalt plants, bitumen terminals, and road construction projects. Our product portfolio includes <strong>PMB plants, bitumen emulsion plants, bitumen melting units, cutback bitumen plants, thermal oil heaters, and auxiliary bitumen equipment<\/strong> designed for reliable and efficient operation.<br><br>Browse the related product categories below to find the right solution for your bitumen storage, heating, and processing requirements.<\/p><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-layout-grid uagb-block-0b3482c1\">\n<div class=\"wp-block-uagb-container uagb-block-kctfoqeu\">\n<div class=\"wp-block-uagb-image aligncenter uagb-block-5f6w3nsq wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-center alignleft\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" src=\"https:\/\/mbaplant.com\/wp-content\/uploads\/2026\/06\/Bitumen-Tank-1024x889.webp\" alt=\"Heated bitumen storage tank with thermal oil circulation system\" class=\"uag-image-18334\" width=\"510\" height=\"300\" title=\"Bitumen Tank\" loading=\"lazy\" role=\"img\" \/><\/figure><\/div>\n\n\n\n<div class=\"wp-block-uagb-info-box uagb-block-cakq8cle uagb-infobox__content-wrap  uagb-infobox-icon-above-title uagb-infobox-image-valign-top\"><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><h3 class=\"uagb-ifb-title\">Bitumen Tank<\/h3><\/div><p class=\"uagb-ifb-desc\"><strong>Bitumen tanks<\/strong> are designed for the safe storage and heating of bitumen at the required operating temperature. Available with electric or hot oil heating systems, they can be manufactured in various capacities to meet different project requirements.<\/p><div class=\"uagb-ifb-button-wrapper wp-block-button\"><a href=\"https:\/\/mbaplant.com\/en\/bitumen-tank\/\" class=\"uagb-infobox-cta-link wp-block-button__link\" target=\"_self\" rel=\"noopener noreferrer\" onclick=\"return true;\"><span class=\"uagb-inline-editing\">View Product Details<\/span><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 512 512\"><path d=\"M504.3 273.6l-112.1 104c-6.992 6.484-17.18 8.218-25.94 4.406c-8.758-3.812-14.42-12.45-14.42-21.1L351.9 288H32C14.33 288 .0002 273.7 .0002 255.1S14.33 224 32 224h319.9l0-72c0-9.547 5.66-18.19 14.42-22c8.754-3.809 18.95-2.075 25.94 4.41l112.1 104C514.6 247.9 514.6 264.1 504.3 273.6z\"><\/path><\/svg><\/a><\/div><\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-f58bd4d1\">\n<div class=\"wp-block-uagb-image aligncenter uagb-block-c786ff26 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-center alignleft\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" src=\"https:\/\/mbaplant.com\/wp-content\/uploads\/2026\/06\/polymer-modified-bitumen-pmb-plant-1024x587.webp\" alt=\"Polymer Modified Bitumen (PMB) Plant for SBS modified asphalt production\" class=\"uag-image-18354\" width=\"510\" height=\"300\" title=\"polymer-modified-bitumen-pmb-plant\" loading=\"lazy\" role=\"img\" \/><\/figure><\/div>\n\n\n\n<div class=\"wp-block-uagb-info-box uagb-block-38b0eaba uagb-infobox__content-wrap  uagb-infobox-icon-above-title uagb-infobox-image-valign-top\"><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><h3 class=\"uagb-ifb-title\">Polymer Modified Bitumen (PMB) Plant<\/h3><\/div><p class=\"uagb-ifb-desc\"><strong>PMB plants<\/strong> are used for the production of high-performance polymer modified bitumen using SBS, APP, EVA, and other polymer additives. These systems ensure homogeneous mixing, accurate dosing, and efficient production processes.<\/p><div class=\"uagb-ifb-button-wrapper wp-block-button\"><a href=\"https:\/\/mbaplant.com\/en\/polymer-modified-bitumen-plant\/\" class=\"uagb-infobox-cta-link wp-block-button__link\" target=\"_self\" rel=\"noopener noreferrer\" onclick=\"return true;\"><span class=\"uagb-inline-editing\">View Product Details<\/span><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 512 512\"><path d=\"M504.3 273.6l-112.1 104c-6.992 6.484-17.18 8.218-25.94 4.406c-8.758-3.812-14.42-12.45-14.42-21.1L351.9 288H32C14.33 288 .0002 273.7 .0002 255.1S14.33 224 32 224h319.9l0-72c0-9.547 5.66-18.19 14.42-22c8.754-3.809 18.95-2.075 25.94 4.41l112.1 104C514.6 247.9 514.6 264.1 504.3 273.6z\"><\/path><\/svg><\/a><\/div><\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-be4415ce\">\n<div class=\"wp-block-uagb-image aligncenter uagb-block-ea4173c8 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-center alignleft\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" src=\"https:\/\/mbaplant.com\/wp-content\/uploads\/2026\/06\/Bitumen-Emulsion-Plant-1024x769.webp\" alt=\"Bitumen Emulsion Plant for producing cationic and anionic bitumen emulsions\" class=\"uag-image-18379\" width=\"510\" height=\"400\" title=\"Bitumen Emulsion Plant\" loading=\"lazy\" role=\"img\" \/><\/figure><\/div>\n\n\n\n<div class=\"wp-block-uagb-info-box uagb-block-ba8b726d uagb-infobox__content-wrap  uagb-infobox-icon-above-title uagb-infobox-image-valign-top\"><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><h3 class=\"uagb-ifb-title\">Bitumen Emulsion Plant<\/h3><\/div><p class=\"uagb-ifb-desc\"><strong>Bitumen emulsion plants<\/strong> are designed for the production of high-quality bitumen emulsions used in road construction and maintenance applications. Automated control systems provide consistent product quality and reliable operation.<\/p><div class=\"uagb-ifb-button-wrapper wp-block-button\"><a href=\"https:\/\/mbaplant.com\/en\/bitumen-emulsion-plant\/\" class=\"uagb-infobox-cta-link wp-block-button__link\" target=\"_self\" rel=\"noopener noreferrer\" onclick=\"return true;\"><span class=\"uagb-inline-editing\">View Product Details<\/span><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 512 512\"><path d=\"M504.3 273.6l-112.1 104c-6.992 6.484-17.18 8.218-25.94 4.406c-8.758-3.812-14.42-12.45-14.42-21.1L351.9 288H32C14.33 288 .0002 273.7 .0002 255.1S14.33 224 32 224h319.9l0-72c0-9.547 5.66-18.19 14.42-22c8.754-3.809 18.95-2.075 25.94 4.41l112.1 104C514.6 247.9 514.6 264.1 504.3 273.6z\"><\/path><\/svg><\/a><\/div><\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-ef0211c6\">\n<div class=\"wp-block-uagb-image aligncenter uagb-block-9a29fe45 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-center alignleft\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" src=\"https:\/\/mbaplant.com\/wp-content\/uploads\/2026\/06\/thermal-oil-boiler-1024x837.webp\" alt=\"Thermal Oil Boiler for bitumen tank heating systems\" class=\"uag-image-18359\" width=\"510\" height=\"400\" title=\"thermal oil boiler\" loading=\"lazy\" role=\"img\" \/><\/figure><\/div>\n\n\n\n<div class=\"wp-block-uagb-info-box uagb-block-dd28251e uagb-infobox__content-wrap  uagb-infobox-icon-above-title uagb-infobox-image-valign-top\"><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><h3 class=\"uagb-ifb-title\">Hot Oil Boiler<\/h3><\/div><p class=\"uagb-ifb-desc\"><strong>Hot oil boilers<\/strong> are used for heating bitumen tanks and industrial process equipment. They provide efficient thermal energy transfer, high operating efficiency, and reliable performance under demanding conditions.<\/p><div class=\"uagb-ifb-button-wrapper wp-block-button\"><a href=\"https:\/\/mbaplant.com\/en\/thermal-oil-boiler\/\" class=\"uagb-infobox-cta-link wp-block-button__link\" target=\"_self\" rel=\"noopener noreferrer\" onclick=\"return true;\"><span class=\"uagb-inline-editing\">View Product Details<\/span><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 512 512\"><path d=\"M504.3 273.6l-112.1 104c-6.992 6.484-17.18 8.218-25.94 4.406c-8.758-3.812-14.42-12.45-14.42-21.1L351.9 288H32C14.33 288 .0002 273.7 .0002 255.1S14.33 224 32 224h319.9l0-72c0-9.547 5.66-18.19 14.42-22c8.754-3.809 18.95-2.075 25.94 4.41l112.1 104C514.6 247.9 514.6 264.1 504.3 273.6z\"><\/path><\/svg><\/a><\/div><\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-4d49c928\">\n<div class=\"wp-block-uagb-image aligncenter uagb-block-985b6d63 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-center alignleft\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" src=\"https:\/\/mbaplant.com\/wp-content\/uploads\/2026\/06\/big-bag-bitumen-decanter-1024x890.webp\" alt=\"Big Bag Bitumen Decanter for melting jumbo bag bitumen\" class=\"uag-image-18374\" width=\"510\" height=\"400\" title=\"big-bag-bitumen-decanter\" loading=\"lazy\" role=\"img\" \/><\/figure><\/div>\n\n\n\n<div class=\"wp-block-uagb-info-box uagb-block-13f22453 uagb-infobox__content-wrap  uagb-infobox-icon-above-title uagb-infobox-image-valign-top\"><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><h3 class=\"uagb-ifb-title\">Big Bag Bitumen Decanter<\/h3><\/div><p class=\"uagb-ifb-desc\">Big Bag Bitumen Decanters are designed to efficiently melt bitumen supplied in jumbo bags and prepare it for transfer to storage or production systems. With high melting capacity, energy-efficient operation, and user-friendly design, these systems provide an ideal solution for bitumen terminals, asphalt plants, and industrial bitumen processing facilities.<\/p><div class=\"uagb-ifb-button-wrapper wp-block-button\"><a href=\"https:\/\/mbaplant.com\/en\/bitumen-bag-decanter\/\" class=\"uagb-infobox-cta-link wp-block-button__link\" target=\"_self\" rel=\"noopener noreferrer\" onclick=\"return true;\"><span class=\"uagb-inline-editing\">View Product Details<\/span><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 512 512\"><path d=\"M504.3 273.6l-112.1 104c-6.992 6.484-17.18 8.218-25.94 4.406c-8.758-3.812-14.42-12.45-14.42-21.1L351.9 288H32C14.33 288 .0002 273.7 .0002 255.1S14.33 224 32 224h319.9l0-72c0-9.547 5.66-18.19 14.42-22c8.754-3.809 18.95-2.075 25.94 4.41l112.1 104C514.6 247.9 514.6 264.1 504.3 273.6z\"><\/path><\/svg><\/a><\/div><\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-b383ae9a\">\n<div class=\"wp-block-uagb-image aligncenter uagb-block-20f82540 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-center alignleft\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" src=\"https:\/\/mbaplant.com\/wp-content\/uploads\/2026\/06\/drum-bitumen-decanter-1024x576.webp\" alt=\"Drum Bitumen Decanter for melting bitumen supplied in steel drums\" class=\"uag-image-18349\" width=\"510\" height=\"400\" title=\"drum-bitumen-decanter\" loading=\"lazy\" role=\"img\" \/><\/figure><\/div>\n\n\n\n<div class=\"wp-block-uagb-info-box uagb-block-cbf3fa7c uagb-infobox__content-wrap  uagb-infobox-icon-above-title uagb-infobox-image-valign-top\"><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><h3 class=\"uagb-ifb-title\">Drum Bitumen Decanter<\/h3><\/div><p class=\"uagb-ifb-desc\">Drum Bitumen Decanters are used for the controlled melting of bitumen stored in steel drums. Their high melting efficiency, low energy consumption, and reliable operation ensure a continuous bitumen supply for asphalt production and bitumen processing applications. These systems are widely preferred for projects where bitumen is delivered in drum packaging.<\/p><div class=\"uagb-ifb-button-wrapper wp-block-button\"><a href=\"https:\/\/mbaplant.com\/en\/bitumen-drum-decanter\/\" class=\"uagb-infobox-cta-link wp-block-button__link\" target=\"_self\" rel=\"noopener noreferrer\" onclick=\"return true;\"><span class=\"uagb-inline-editing\">View Product Details<\/span><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 512 512\"><path d=\"M504.3 273.6l-112.1 104c-6.992 6.484-17.18 8.218-25.94 4.406c-8.758-3.812-14.42-12.45-14.42-21.1L351.9 288H32C14.33 288 .0002 273.7 .0002 255.1S14.33 224 32 224h319.9l0-72c0-9.547 5.66-18.19 14.42-22c8.754-3.809 18.95-2.075 25.94 4.41l112.1 104C514.6 247.9 514.6 264.1 504.3 273.6z\"><\/path><\/svg><\/a><\/div><\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-90dfe600\">\n<div class=\"wp-block-uagb-image aligncenter uagb-block-51489a30 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-center alignleft\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" src=\"https:\/\/mbaplant.com\/wp-content\/uploads\/2026\/06\/wet-mix-macadam-wmm-plant.webp\" alt=\"Wet Mix Macadam (WMM) Plant for road base and sub-base material production\" class=\"uag-image-18369\" width=\"510\" height=\"300\" title=\"wet-mix-macadam-wmm-plant\" loading=\"lazy\" role=\"img\" \/><\/figure><\/div>\n\n\n\n<div class=\"wp-block-uagb-info-box uagb-block-e352f346 uagb-infobox__content-wrap  uagb-infobox-icon-above-title uagb-infobox-image-valign-top\"><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><h3 class=\"uagb-ifb-title\">Wet Mix Macadam (WMM) Plant<\/h3><\/div><p class=\"uagb-ifb-desc\">Wet Mix Macadam (WMM) Plants are designed for the accurate proportioning and mixing of aggregates, water, and additives to produce high-quality road base and subbase materials. These plants provide high production capacity, reliable operation, and consistent mixture quality for road construction and infrastructure projects.<\/p><div class=\"uagb-ifb-button-wrapper wp-block-button\"><a href=\"https:\/\/mbaplant.com\/en\/wet-mix-macadam-plant\/\" class=\"uagb-infobox-cta-link wp-block-button__link\" target=\"_self\" rel=\"noopener noreferrer\" onclick=\"return true;\"><span class=\"uagb-inline-editing\">View Product Details<\/span><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 512 512\"><path d=\"M504.3 273.6l-112.1 104c-6.992 6.484-17.18 8.218-25.94 4.406c-8.758-3.812-14.42-12.45-14.42-21.1L351.9 288H32C14.33 288 .0002 273.7 .0002 255.1S14.33 224 32 224h319.9l0-72c0-9.547 5.66-18.19 14.42-22c8.754-3.809 18.95-2.075 25.94 4.41l112.1 104C514.6 247.9 514.6 264.1 504.3 273.6z\"><\/path><\/svg><\/a><\/div><\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-bed1f070\">\n<div class=\"wp-block-uagb-image aligncenter uagb-block-0b5139fb wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-center alignleft\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" src=\"https:\/\/mbaplant.com\/wp-content\/uploads\/2026\/06\/cutback-bitumen-plant-1024x700.webp\" alt=\"Cutback Bitumen Plant for blending bitumen and solvents\" class=\"uag-image-18344\" width=\"510\" height=\"300\" title=\"cutback-bitumen-plant\" loading=\"lazy\" role=\"img\" \/><\/figure><\/div>\n\n\n\n<div class=\"wp-block-uagb-info-box uagb-block-043ea9a3 uagb-infobox__content-wrap  uagb-infobox-icon-above-title uagb-infobox-image-valign-top\"><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><h3 class=\"uagb-ifb-title\">Cutback Bitumen Plant<\/h3><\/div><p class=\"uagb-ifb-desc\">Cutback Bitumen Plants are designed for the controlled blending of bitumen and solvents to produce high-quality cutback bitumen. Equipped with precise dosing and automated process control systems, these plants ensure consistent product quality for road construction, maintenance, and surface treatment applications.<\/p><div class=\"uagb-ifb-button-wrapper wp-block-button\"><a href=\"https:\/\/mbaplant.com\/en\/cutback-bitumen-plant\/\" class=\"uagb-infobox-cta-link wp-block-button__link\" target=\"_self\" rel=\"noopener noreferrer\" onclick=\"return true;\"><span class=\"uagb-inline-editing\">View Product Details<\/span><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 512 512\"><path d=\"M504.3 273.6l-112.1 104c-6.992 6.484-17.18 8.218-25.94 4.406c-8.758-3.812-14.42-12.45-14.42-21.1L351.9 288H32C14.33 288 .0002 273.7 .0002 255.1S14.33 224 32 224h319.9l0-72c0-9.547 5.66-18.19 14.42-22c8.754-3.809 18.95-2.075 25.94 4.41l112.1 104C514.6 247.9 514.6 264.1 504.3 273.6z\"><\/path><\/svg><\/a><\/div><\/div><\/div>\n<\/div>\n<\/div>\n<\/div><\/section>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Frequently Asked Questions About Bitumen Storage Pits Find answers to the most frequently asked questions about reinforced concrete bitumen storage pits, thermal oil heating systems, storage capacities, applications, and engineering solutions.<\/p>\n","protected":false},"author":1,"featured_media":20253,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_zipai_imported":false,"_joinchat":[],"footnotes":""},"class_list":["post-20248","page","type-page","status-publish","has-post-thumbnail","hentry"],"spectra_blocks_featured_image_url":{"thumbnail":{"url":"https:\/\/mbaplant.com\/wp-content\/uploads\/2026\/07\/Bitumen-storage-pit-150x150.webp","width":150,"height":150},"medium":{"url":"https:\/\/mbaplant.com\/wp-content\/uploads\/2026\/07\/Bitumen-storage-pit-300x169.webp","width":300,"height":169},"medium_large":{"url":"https:\/\/mbaplant.com\/wp-content\/uploads\/2026\/07\/Bitumen-storage-pit-768x432.webp","width":768,"height":432},"large":{"url":"https:\/\/mbaplant.com\/wp-content\/uploads\/2026\/07\/Bitumen-storage-pit-1024x576.webp","width":1024,"height":576},"full":{"url":"https:\/\/mbaplant.com\/wp-content\/uploads\/2026\/07\/Bitumen-storage-pit.webp","width":1672,"height":941}},"spectra_blocks_author_info":{"display_name":"mbayonetici","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/cd075727a3f44baf47681957cc27975159b91be3675f3e65c220600811aa9d4b?s=96&d=mm&r=g","author_link":"https:\/\/mbaplant.com\/en\/author\/mbayonetici\/","description":""},"uagb_featured_image_src":{"full":["https:\/\/mbaplant.com\/wp-content\/uploads\/2026\/07\/Bitumen-storage-pit.webp",1672,941,false],"thumbnail":["https:\/\/mbaplant.com\/wp-content\/uploads\/2026\/07\/Bitumen-storage-pit-150x150.webp",150,150,true],"medium":["https:\/\/mbaplant.com\/wp-content\/uploads\/2026\/07\/Bitumen-storage-pit-300x169.webp",300,169,true],"medium_large":["https:\/\/mbaplant.com\/wp-content\/uploads\/2026\/07\/Bitumen-storage-pit-768x432.webp",768,432,true],"large":["https:\/\/mbaplant.com\/wp-content\/uploads\/2026\/07\/Bitumen-storage-pit-1024x576.webp",1024,576,true],"1536x1536":["https:\/\/mbaplant.com\/wp-content\/uploads\/2026\/07\/Bitumen-storage-pit-1536x864.webp",1536,864,true],"2048x2048":["https:\/\/mbaplant.com\/wp-content\/uploads\/2026\/07\/Bitumen-storage-pit.webp",1672,941,false]},"uagb_author_info":{"display_name":"mbayonetici","author_link":"https:\/\/mbaplant.com\/en\/author\/mbayonetici\/"},"uagb_comment_info":0,"uagb_excerpt":"Frequently Asked Questions About Bitumen Storage Pits Find answers to the most frequently asked questions about reinforced concrete bitumen storage pits, thermal oil heating systems, storage capacities, applications, and engineering solutions.","_links":{"self":[{"href":"https:\/\/mbaplant.com\/en\/wp-json\/wp\/v2\/pages\/20248","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mbaplant.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/mbaplant.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/mbaplant.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/mbaplant.com\/en\/wp-json\/wp\/v2\/comments?post=20248"}],"version-history":[{"count":6,"href":"https:\/\/mbaplant.com\/en\/wp-json\/wp\/v2\/pages\/20248\/revisions"}],"predecessor-version":[{"id":22720,"href":"https:\/\/mbaplant.com\/en\/wp-json\/wp\/v2\/pages\/20248\/revisions\/22720"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/mbaplant.com\/en\/wp-json\/wp\/v2\/media\/20253"}],"wp:attachment":[{"href":"https:\/\/mbaplant.com\/en\/wp-json\/wp\/v2\/media?parent=20248"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}